Atomic Absorption Spectrophotometer AAS-185LS

Atomic Absorption Spectrophotometer AAS-185LS

Atomic Absorption Spectrophotometer AAS-185LS offers a wavelength range from 185 to 900 nm with an accuracy of ± 0.15 nm. It features an automatic gas control system for smooth operation. This device provides vertical optical temperature monitoring for graphite tube wall detection. It supports automatic temperature control with multiple programmable orders. Its efficient atomization and detection system make it ideal for metal analysis. Our atomic absorption spectrophotometer provides precise metal analysis with advanced automation and safety. 

Wavelength Range

$36,700 / Each of 1

Get PDF
  • Microcomputer controlled

  • Easy operation

  • Automatic Ignition

  • Fully enclosed optical system

  • Low maintenance with durable design

Wavelength Range 185 to 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 0.7 nm, 1.0 nm, 1.4 nm, 2.0 nm automatic setting
Wavelength Accuracy ± 0.15 nm
Wavelength Repeatability < 0.1 nm
Baseline Drift ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
Absorbance Range 0 to 4 A
The Program Automatic temperature control up to 20 orders
Temperature Range Room temperature to 3000 ℃
Detector Imported photomultiplier tube
Heating Mode Vertical heating
Temperature Control Method Vertical optical temperature monitoring graphite tube wall temperature
Temperature Control The furnace enriched up to 20 times
Lamp Holder ≤ 8 lamps automatic turret, automatic alignment
Lamp Power Supply Mode Pulsed power supply
Optical System Large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume 0.4 × 10-12g (Cd)
Detection Limit 0.4 × 10-12g (Cd)
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer, can also be customized
Precision RSD ≤ 0.5 %
Safety Measures The graphite tube damage, water flow Air pressure and other alarm temperature overheating protection
Cooling Water Can choose cooling water circulation system
Power Supply 110 / 220 V (+5 % to -10 %), 60 / 50 Hz; 5000 VA

Our Atomic Absorption Spectrophotometer AAS-185LS is widely used for metal analysis in food, petroleum, chemical, and pharmaceutical industries. It ensures accurate detection of trace elements in liquids and solutions.

Atomic Absorption Spectrophotometer

Submit your inquiry.

our experts will promptly respond to you.