Blood Gas Analyzer BGS-150LS measures ten parameters from a 150 μL blood sample and completes the testing process within 3 minutes. It features an 8.9-inch LCD 480p capacitive touch screen for intuitive navigation. Our analyzer has no fluidic pathways, ensuring hassle-free operation and minimal maintenance. It integrates with LIS/HIS for seamless data management. Includes a barcode scanner and thermal printer for efficient sample identification and result printing.
Sample TypeCompact and portable
Microfluidic electrochemical technology
Test cartridges can be stored up to 8 months
Instant operation
Minimum sample volume requirement
Rechargeable lithium battery
Sample Type | Arterial and venous blood |
Blood Sample Volume | 150 μL |
Principle Method | Dry electrochemistry/microfluidic method |
Test Time | 5 ± 1 min (including calibration) |
Test Parameters | pH, pCO₂, pO₂, K⁺, Na⁺, Cl⁻, iCa²⁺, Glucose, Lactate, Hct. |
Operating Temperature | 10 ℃ to 30 ℃ |
Measured Parameter | Hydrogen ion activity (pH): 6.500 to 8.000 pH Carbon dioxide Partial pressure (pCO₂): 10.0 to 150.0 mmHg Oxygen partial pressure (PO₂): 10 to 700 mmHg Potassium ion (K): 2.0 to 9.0 mmol/L Sodium ion (Na): 100 to 180 mmol/L Chloride ion (Cl): 65 to 140 mmol/L Ionized calcium (Ca): 0.25 to 2.50 mmol/L Hct: 10% to 70% PCV Glucose: 1.1 to 38.0 mmol/L Lactate: 0.50 to 20.00 mmol/L |
Derived Parameters | cH⁺ (T), pH (T), pCO₂ (T), pO₂ (T), pO₂ (A-a) (T), pO₂ (a/A) (T), RI (T), pO₂ (T) / FiO₂, cH⁺, iCa²⁺ (7.4), HCO₃⁻-act, HCO₃⁻-std, BE (ecf), BE (B), BB (B), AG, sO₂ (est), tHb (est), TCO₂, pO₂ (A-a), pO₂ (a/A), RI, mOsm, and pO₂ / FiO₂ |
Hematocrit Range | Blood glucose test: HCT range 10% to 65% Blood lactate test: HCT range 30% to 60% |
Data Storage | 100,000 test results and 10,000 quality control results |
Cartridge Storage Condition | Room temperature up to 8 months |
Display Screen | 8.9-inch LCD 480p capacitive touch screen |
Battery Type | Rechargeable lithium battery |
Duration | Continuous standby: 24 hours Continuous times: ≥ 60 times |
Rated Energy | < 98 Wh |
Voltage | ≥ 16.8V |
Dimensions | 235 × 210 × 160 mm |
Weight | 3.0 ± 0.5kg (including battery) |
Blood gas cartridge
Critical Care Monitoring-used in intensive care units to monitor patient acid-base balance, oxygenation, and ventilation status
Neonatal Care- helps to check blood gases in newborns for respiratory and metabolic health
Research and Clinical Trials-utilized in research settings to study blood gas levels in various conditions