Chemiluminescence Imaging System CIS-800LS incorporates a 16-bit CCD camera that effectively reduces background noise, especially during prolonged exposure periods. Equipped with a F0.8 motorized lens and 12.49 × 9.99 mm CCD sensor size for accurate imaging with increased light sensitivity. It is designed to offer a wider linear range for improved signal detection with greater precision. Provided with 10.1-inch touch screen display, offering a user-friendly interface for intuitive operation.
LensCapable of detecting weaker signals
Automated pixel grouping technology
Easy image navigation and browsing
Optional attachment of fluorescent light sources and filters
Occupies a small footprint
Composition and capture of objective band marker images
Captures faint bands on blots with maximum sensitivity
Optional full-system configuration for analysis (DNA, RNA, Protein, Chemiluminescence, Fluorescence)
Lens | F0.8 motorized lens |
CCD Sensor Size | 12.49 × 9.99 mm |
Resolution | 6.05 Megapixels, 2750 × 2200 |
Pixel Density | 16bit (65536 Grey Scales) |
Pixel Size | 4.54 × 4.54 µm |
Light Source | LED Epi-white light × 2 UV-Transilluminator (302 nm) White-LED Transilluminator |
Quantum Efficiency | ≥ 75 % |
Readout Noise | < 5.5e- RMS |
Dark Current | 0.0003 e/p/s |
Dynamic Range | 4 order of magnitude |
Standard Filter | 590 nm filter |
Filter Wheel | 8 Sockets Filter Wheel |
Max Image Area | 260 × 210 mm |
Cooling Temperature | -30˚C |
Software | Image acquisition and analysis software |
Internal Dimension | 380 × 350 × 490 mm |
External Dimension | 560 × 480 × 780 mm |
Weight | 39 kg |
Molecular Biology: Used for DNA and RNA analysis, gene expression studies, and genetic research.
Immunology: Enables analysis of immune responses, antibody detection, and immunoblotting.
Cell Biology: Utilized for cell-based assays, studying cellular processes, and cell imaging.
High precision automatic exposure
Enables image capture and saving with just one touch
Automatic access of capture parameters
Auto calculation of band density and peak values
Convenient image navigation and browsing
Adopts image rotation, cropping, and color correction
Automatic recognition of the gel bands
Advanced pixel binning technology
Optional saving of analysis results as Excel files
Optical density calculation for quantitative analysis
Optimizes visual effects by removing background mode