Phone: +14514152142 Request A Quote WhatsApp: +9524 2685 2142
Chemiluminescence Imaging System CIS-80LS

Chemiluminescence Imaging System CIS-80LS

Chemiluminescence Imaging System CIS-80LS integrates a high quantum efficiency CCD camera enhancing detection capabilities through improved sensitivity and dynamic range. With 12.49 × 9.99 mm CCD sensor, it provides a resolution of 6.005 megapixels, ensuring precise and detailed image capturing. This 16-bit CCD camera, capable of 65536 Grey Scales, reduces background noise during long exposure periods.

Lens

Get PDF
  • Convenient image navigation and browsing 

  • Offers wider linear range and detect weaker signals

  • Automated pixel grouping technology

  • Composition and capture of objective band marker images

  • Optional attachment of fluorescent light sources and filters

  • Occupies less space 

  • Captures faint bands on blots with maximum sensitivity

  • Optional full-system configuration for analysis (DNA, RNA, Protein, Chemiluminescence, Fluorescence)

Lens F0.8 motorized lens
CCD Sensor Size 12.49 × 9.99 mm
Resolution 6.05 Megapixels, 2750 × 2200
Pixel Density 16bit (65536 Grey Scales)
Pixel Size 4.54 × 4.54 µm
Light Source LED Epi-white light × 2
UV-Transilluminator (302 nm)
White-LED Transilluminator
Display NA
Quantum Efficiency ≥ 75 %
Readout Noise < 5.5e- RMS
Dark Current 0.0003 e/p/s
Dynamic Range 4 order of magnitude
Standard Filter 590 nm filter
Filter Wheel 8 Sockets Filter Wheel
Max Image Area 260 × 210 mm
Cooling Temperature -30˚C
Software Image acquisition and analysis software
Internal Dimension 380 × 350 × 490 mm
External Dimension 560 × 480 × 780 mm
Weight 39 kg

Molecular Biology: Used for DNA and RNA analysis, gene expression studies, and genetic research.

Immunology: Enables analysis of immune responses, antibody detection, and immunoblotting.

Cell Biology: Utilized for cell-based assays, studying cellular processes, and cell imaging.

High precision automatic exposure

Enables image capture and saving with just one touch

Automatic access of capture parameters

Auto calculation of band density and peak values

Convenient image navigation and browsing

Adopts image rotation, cropping, and color correction

Automatic recognition of the gel bands

Advanced pixel binning technology

Optional saving of analysis results as Excel files

Optical density calculation for quantitative analysis

Optimizes visual effects by removing background mode

Be the first to provide a review.

Write Your Review



Be the first to pose a question.

0 / 150 words

No Q&A

Chemiluminescence Imaging System

Submit your inquiry.

our experts will promptly respond to you.