Chemiluminescence Imaging System CIS-950LS integrates a 12.49 × 9.99 mm CCD Sensor Size, with 6.05 MP resolution for excellent imaging performance. It is designed with a F0.95 motorized lens offering exceptional light-gathering capabilities and precise adjustments for optimal image quality. With its 16-bit CCD camera, capturing 65,536 shades of gray, it effectively reduces background noise in long exposures. It is equipped with a 10.1-inch touch screen display, providing a user-friendly interface for intuitive operation.
LensAutomated pixel grouping technology
Provides wider linear range and detect weaker signals
Easy image navigation and browsing
High quantum efficiency CCD camera
Optional attachment of fluorescent light sources and filters
Captures faint bands on blots with maximum sensitivity
Composition and capture of objective band marker images
Optional full-system configuration for analysis (DNA, RNA, Protein, Chemiluminescence, Fluorescence)
Lens | F0.95 motorized lens |
CCD Sensor Size | 12.49 × 9.99 mm |
Resolution | 6.05 Megapixels, 2750 × 2200 |
Pixel Density | 16bit (65536 Grey Scales) |
Pixel Size | 4.54 × 4.54 µm |
Light Source | LED Epi-white light × 2 UV-Transilluminator (302 nm) White-LED Transilluminator |
Quantum Efficiency | ≥ 75 % |
Readout Noise | < 5.5e- RMS |
Dark Current | 0.0003 e/p/s |
Dynamic Range | 4 order of magnitude |
Standard Filter | 590 nm filter |
Filter Wheel | 8 Sockets Filter Wheel |
Max Image Area | 260 × 210 mm |
Cooling Temperature | -30˚C |
Software | Image acquisition and analysis software |
Internal Dimension | 380 × 350 × 490 mm |
External Dimension | 560 × 480 × 780 mm |
Weight | 39 kg |
Molecular Biology: Used for DNA and RNA analysis, gene expression studies, and genetic research.
Immunology: Enables analysis of immune responses, antibody detection, and immunoblotting.
Cell Biology: Utilized for cell-based assays, studying cellular processes, and cell imaging.
High precision automatic exposure
Enables image capture and saving with just one touch
Automatic access of capture parameters
Auto calculation of band density and peak values
Convenient image navigation and browsing
Adopts image rotation, cropping, and color correction
Automatic recognition of the gel bands
Advanced pixel binning technology
Optional saving of analysis results as Excel files
Optical density calculation for quantitative analysis
Optimizes visual effects by removing background mode
Be the first to provide a review.
Write Your Review
Be the first to pose a question.
No Q&A
Submit your inquiry.
our experts will promptly respond to you.