Fetal Monitor FTM-50LS

Fetal Monitor FTM-50LS

Fetal Monitor FTM-50LS detects fetal heart rates within a range of 50 to 240 beats per minute with an accuracy of ±2 bpm. Features a large 12.1-inch TFT color screen to display various parameters for FHR, TOCO, and fetal movement. Equipped with a special high-sensitive transducer that operates at a frequency of 1.0MHz. Our monitor’s screen can be adjusted and folded up to 90 degrees, providing flexibility in viewing angles. It can store up to 42 hours of data, with playback and print options.

Parameters

Get PDF

Compact and lightweight 

Integrated alarm system

Low Ultrasound Power Operation

Utilizes DSP technology 

Can be connected to an obstetrical central station

Features automatic FM testing

Parameters Fetal Heart Rate 1 (FHR), FHR2
FHR Measurement Range 50 to 240 bpm
FHR Accuracy ± 2 bpm
FHR Sweep Speed X1, X2, X4, X8
Transducer 9 crystals, pulsed Doppler,
Transducer Frequency 1.0MHz
Transducer Probe wired
Uterine Activity Measurement Range 0 to 100
Uterine Activity Baseline 0, 5, 10, 15, 20 (selectable)
Maternal ECG/HR (MECG) Lead Type 5-lead
MECG Lead Selection RA, LA, RL, LL, V
HR Measurement Range 15 bpm to 300 bpm
HR Accuracy ±1 bpm or ±1 %,
Respiration Rate Range 7 rpm to 120 rpm
Respiration Accuracy ±2 rpm/min or ±2 %
Non-Invasive Blood Pressure (NIBP) Method Automatic Oscillo metric
NIBP Parameters SYS/DIA/MAP
NIBP Operating Modes Manual/Auto
NIBP Auto Measure Intervals 3/5/10/20/30/60/90/120/240 minutes
NIBP Units mmHg/kPa
NIBP Cuff Pressure Range 0 mmHg to 300 mmHg (0 kPa - 40.0 kPa)
Measurement And Alarm Range SYS: 50 mmHg - 240 mmHg (6.7 kPa - 32.0 kPa)
MAP: 25 mmHg - 200 mmHg (3.4 kPa - 26.6 kPa)
DIA: 15 mmHg - 180 mmHg (2.0 kPa - 24.0 kPa)
NIBP Accuracy ±3 mmHg (±0.4 kPa) or ±2 of reading
Over-Pressure Protection Yes
Maternal SpO2 Measurement Range 70 to 99 %
Maternal SpO2 Accuracy ± 3 %
PR Range 30 to 240 bpm
PR Accuracy ±2 bpm/min or ±5 % reading
Temperature Range 0 to 50℃
Temperature Resolution ± 0.1℃
Battery 2200mAh/14.8V Li-Ion battery
Battery Life 4 hours
Power Supply 100 to 240V
Dimensions (L × W × H) 350 × 320 × 85 mm
Weight 3.5kg

Three-in-one probe

FHR probe

Uterine contraction pressure probe

Fetal movement mark button

FHR secondary probe: for twins

Fetal wake-up device

Blood oxygen finger cot

NIBP cuff

ECG cable

Insurance tube

Power cord

Thermal printing paper

Belt

Twins Probe

Fetus Waker

Touch Screen

Trolley

Wall Bracket

Obstetrics and Gynecology-used to monitor fetal heart rate and uterine contractions during labor to ensure the safety of both the mother and the baby

Neonatal Intensive Care Units- employed to detect the fetal heart rate in newborns requiring specialized care due to prematurity and birth complications

Research and Education- helps to improve prenatal care and labor management through studies in obstetrics, maternal-fetal medicine, and neonatology