Phone: +14514152142 Request A Quote WhatsApp: +9524 2685 2142
Ion Chromatograph System ICS-35LS

Ion Chromatograph System ICS-35LS

Ion Chromatograph System ICS-35LS is integrated with the Bipolar Conductivity Detector (BCD) that can measure conductivity within a range from 0 to 35,000 µS/cm. It offers an adjustable flow rate of  0.001 to 9.999 ml/min optimizing separation and retention of analytes. Our chromatograph system maintains thermal stability ensuring reliability, reproducibility, and accuracy of analytical results.

Detection Range

Get PDF
  • Incorporated with eluent generator

  • Built-in low-pressure degassing technology

  • Self-regenerating electrolytic microfilm suppressor

  • Features automatic standard dilution

Detection Range 0 to 35000 µS/ cm
Ion Pump Pressure 35 MPa
Pressure Accuracy ≤ 0.1 MPa
Flow Stability 0.2 to 0.5 ml/ min ≤ 3 %
0.5 to 1.0 ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow Range 0.001 to 9.999 ml/ min
Pressure Pulse ≤ 0.5%
Detection Mode Bipolar conductivity detection
Cell Volume ≤ 0.8 µL
Detection Resolution ≤ 0.0020 nS/ cm
Output Voltage - 6000 to +6000 mV (adjustable)
Baseline Noise ≤ 0.05 % F.S
Baseline Drift ≤ 3 % FS/ 30 min
Temperature Range Room temperature ± 5 to 60°C
Temperature Accuracy ± 0.01°C
Pressure 10 MPa
Linear Range ≥ 103
Linearity ≥ 0.999
Quantitative Repeatability ≤ 1.0 %
Qualitative Repeatability ≤ 1.0 %
Minimum Detectable Concentration Cl ≤ 0.0005 ug/ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow System PEEK materials
Six-Way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function
Degassing Inner Volume 300 µl
Degassing Volume 7.5 ml
Maximum Flow Rate 10 ml/ min
Degassing Efficiency 90 % at 1ml/ min
Organic Tolerance 1
Eluent Types KOH/ NaOH
Eluent Concentration Range 0.1 to 100 mM
Concentration Increment 0.1 mM
Flow Rate Change 0.1 to 3.0 ml/ min
Maximum Pressure 20 MPa
Minimum Pressure 5 MPa
Power 150 W
Dimension 350 × 470 × 650 mm
Net Weight 34 kg
Gross Weight 40 kg

Ion Chromatography Host

1

High-Pressure Advection Pump

1

Conductivity Detector

1

Anion Column

1

Anion Guard Column

1

Suppressor

1

Chromatography Workstation

1

Column Thermostat System

1

Spare Parts Kits

1

Vacuum Degassing Pump

1

Sand Core Filtration Devices

1

Pretreatment Column

20

0.22 µm Syringe Filter

200

Eluent Generator

1

1Autosampler (20 Samples)
3Autosampler (108 Samples)
4Anion Column
5Guard Column
6Anion Suppressor
7Spare Parts Kits

 

Environmental Analysis- Determination of anions and cations in environmental samples

Water Quality Monitoring- Analysis of anions and cations in industrial effluents.

Food and Beverage Analysis- Determination of organic acids, preservatives, sweeteners, and other additives in food and beverage products

Pharmaceutical Analysis- Quantification of inorganic ions, such as chloride, sulphate, and phosphate

Be the first to provide a review.