Ion Chromatograph System ICS-45LS is equipped with a Bipolar Conductivity Detector (BCD) capable of measuring conductivity across a range of 0 to 45,000 µS/cm. It provides an adjustable flow rate ranging from 0.001 to 9.999 ml/min, optimizing the separation of analytes. Our chromatograph system has built-in stereo constant temperature control that provides precise and stable temperature control conditions for accurate results.
Detection RangeIntegrated with advanced control systems
Provides large column capacity
High pressure and low pulse double plunger pump
Self-regenerating electrolytic microfilm suppressor
Features automatic standard dilution
Detection Range | 0 to 45000 µS/ cm |
Pressure Accuracy | ≤ 0.1 MPa |
Flow Stability | 0.2 to 0.5ml/ min ≤ 3 % 0.5 to 1.0ml/ min ≤ 2 % >1.0 ml/ min 2 % |
Flow Range | 0.001 to 9.999 ml/ min |
Pressure Pulse | ≤ 0.5% |
Detection Mode | Bipolar Conductivity Detector |
Cell Volume | ≤ 0.8 µL |
Detection Resolution | ≤ 0.0020 nS/ cm |
Output Voltage | - 6000 to +6000 mV (adjustable) |
Baseline Noise | ≤ 0.05 % F.S. |
Baseline Drift | ≤ 3 % FS/ 30 min |
Temperature Range | Room temperature +5 to 60°C (41 to 140°F) |
Temperature Accuracy | ± 0.01°C |
Pressure | 10 MPa |
Linear Range | ≥ 103 |
Linearity | ≥ 0.999 |
Quantitative Repeatability | ≤ 1.0 % |
Qualitative Repeatability | ≤ 1.0 % |
Minimum Detectable Concentration | Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml |
Flow System | Made of PEEK materials |
Six-Way Valve | PEEK material, 5000 psi pressure, independent automatic collection and flow function |
Power | 150 W |
Dimension | 350 × 470 × 650 mm |
Net Weight | 26 kg |
Gross Weight | 32 kg |
Accessories Name | Quantity |
Ion Chromatography host | 1 |
High pressure advection pump | 1 |
Conductivity detector | 1 |
Anion column | 1 |
Anion guard column | 1 |
Suppressor | 1 |
Chromatography workstation | 1 |
Column thermostat system | 1 |
Spare parts kits | 1 |
Vacuum degassing pump | 1 |
Sand core filtration devices | 1 |
Pretreatment column | 20 |
0.22 µm syringe filter | 200 |
Autosampler (20 Samples) |
Autosampler (54 Samples) |
Autosampler (108 Samples) |
Anion Column |
Guard Column |
Anion Suppressor |
Spare Parts Kits |
Environmental Analysis- Determination of anions and cations in environmental samples
Water Quality Monitoring- Analysis of anions and cations in industrial effluents.
Food and Beverage Analysis- Determination of organic acids, preservatives, sweeteners, and other additives in food and beverage products
Pharmaceutical Analysis- Quantification of inorganic ions, such as chloride, sulphate, and phosphate
Be the first to provide a review.
Write Your Review
Be the first to pose a question.
No Q&A
Submit your inquiry.
our experts will promptly respond to you.