Phone: +14514152142 Request A Quote WhatsApp: +9524 2685 2142
Ion Chromatograph System ICS-45LS

Ion Chromatograph System ICS-45LS

Ion Chromatograph System ICS-45LS is equipped with a Bipolar Conductivity Detector (BCD) capable of measuring conductivity across a range of 0 to 45,000 µS/cm. It provides an adjustable flow rate ranging from 0.001 to 9.999 ml/min, optimizing the separation of analytes. Our chromatograph system has built-in stereo constant temperature control that provides precise and stable temperature control conditions for accurate results. 

Detection Range

Get PDF
  • Integrated with advanced control systems

  • Provides large column capacity

  • High pressure and low pulse double plunger pump

  • Self-regenerating electrolytic microfilm suppressor

  • Features automatic standard dilution

Detection Range 0 to 45000 µS/ cm
Pressure Accuracy ≤ 0.1 MPa
Flow Stability 0.2 to 0.5ml/ min ≤ 3 %
0.5 to 1.0ml/ min ≤ 2 %
>1.0 ml/ min 2 %
Flow Range 0.001 to 9.999 ml/ min
Pressure Pulse ≤ 0.5%
Detection Mode Bipolar Conductivity Detector
Cell Volume ≤ 0.8 µL
Detection Resolution ≤ 0.0020 nS/ cm
Output Voltage - 6000 to +6000 mV (adjustable)
Baseline Noise ≤ 0.05 % F.S.
Baseline Drift ≤ 3 % FS/ 30 min
Temperature Range Room temperature +5 to 60°C (41 to 140°F)
Temperature Accuracy ± 0.01°C
Pressure 10 MPa
Linear Range ≥ 103
Linearity ≥ 0.999
Quantitative Repeatability ≤ 1.0 %
Qualitative Repeatability ≤ 1.0 %
Minimum Detectable Concentration Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow System Made of PEEK materials
Six-Way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function
Power 150 W
Dimension 350 × 470 × 650 mm
Net Weight 26 kg
Gross Weight 32 kg

Accessories Name

Quantity

Ion Chromatography host

1

High pressure advection pump

1

Conductivity detector

1

Anion column

1

Anion guard column

1

Suppressor

1

Chromatography workstation

1

Column thermostat system

1

Spare parts kits

1

Vacuum degassing pump

1

Sand core filtration devices

1

Pretreatment column

20

0.22 µm syringe filter

200

Autosampler (20 Samples)

Autosampler (54 Samples)

Autosampler (108 Samples)

Anion Column

Guard Column

Anion Suppressor

Spare Parts Kits

 

Environmental Analysis- Determination of anions and cations in environmental samples 

Water Quality Monitoring- Analysis of anions and cations in industrial effluents.

Food and Beverage Analysis- Determination of organic acids, preservatives, sweeteners, and other additives in food and beverage products

Pharmaceutical Analysis- Quantification of inorganic ions, such as chloride, sulphate, and phosphate

Be the first to provide a review.

Write Your Review



Be the first to pose a question.

0 / 150 words

No Q&A

Ion Chromatograph System

Submit your inquiry.

our experts will promptly respond to you.