Ion Chromatograph System ICS-50LS

Ion Chromatograph System ICS-50LS

Ion Chromatograph System ICS-50LS is incorporated with the Bipolar Conductivity Detector and offers precise conductivity measurement capabilities spanning from 0 to 50,000 µS/cm. Our chromatograph system is designed with an autosampler which automates sample introduction, increasing the efficiency of the analysis process. It consists of an adjustable flow range of 0.001 to 9.999 ml/min for reliable quantification and identification of analytes.

Detection Range

Get PDF
  • Incorporated with eluent generator

  • Dual channel design

  • High pressure and low pulse double plunger pump

  • Thermal buffer system for eluent

  • Built-in low-pressure degassing technology

  • Features an automatic cleaning mode

  • Single operation for switching flow paths
Detection Range 0 to 50000 µS/ cm
Ion Pump Pressure 35 MPa
Pressure Accuracy ≤ 0.1 MPa
Flow Stability 0.2 to 0.5ml/ min ≤ 3 %
0.5 to 1.0 ml/ min ≤ 2 %
> 1.0 ml/ min ≤ 2 %
Flow Range 0.001 to 9.999 ml/ min
Pressure Pulse ≤ 0.5 %
Electromagnetic Injection Pressure 35 MPa
Rotor Material PEEK
Control Mode By Stepper motor
Power Supply DC 24 V
Column Heater Temperature Range Room temperature 20 to 60°C
Column Heater Temperature Accuracy ± 0.01°C
Allowable Deviation of Column Heater Temperature ± 2°C
Temperature Stability ≤ 1°C/ h
Six-Way Valve PEEK material pressure 5000 psi, independent automatic collection, and flow function
Buffer System Temperature Range 25°C to 40°C
Degassing Device Type Built-in low pressure
Vacuum Degree -70 kPa
Maximum Flow Rate 10 ml/ min
Internal Volume 30 µl
Degassing Efficiency 10 ml/ min 90 %
Detection Mode Bipolar conductivity detection
Cell Volume ≤ 0.8 µl
Output Voltage -6000 to +6000 mV (adjustable)
Operating Temperature Room temperature 5 to 60°C
Temperature Accuracy ± 0.01°C
Pressure 10 MPa
Linear Range ≥ 103
Linearity ≥ 0.999
Quantitative Repeatability ≤ 1.0 %
Qualitative Repeatability ≤ 1.0 %
Eluent Type KOH/ NaOH
Eluent Concentration Range 0.1 to 100 mM 0.1 to 100 mM
Concentration Increment 0.1 mM
Flow Rate Change 0.1 to 3.0 ml/ min
Maximum Pressure 20 MPa
Minimum Pressure 5 MPa
HS Code 9027201200
Power Consumption 150 W
Power Supply DC 220 V, 60 Hz
Dimension 500 × 500 × 760 mm
Net Weight 48 kg
Gross Weight 73 kg

 

Anion column

Guard column

Anion Suppressor

UV detector

Ampere detector

Autosampler (108) samples

 

 

 

Environmental Analysis- Determination of anions and cations in environmental samples 

Water Quality Monitoring- Analysis of anions and cations in industrial effluents.

Food and Beverage Analysis- Determination of organic acids, preservatives, sweeteners, and other additives in food and beverage products

Pharmaceutical Analysis- Quantification of inorganic ions, such as chloride, sulphate, and phosphate