Labtron Laser Particle Analyzers offer dual dispersion types to cater to different sample requirements. With variable channel numbers, it provides flexibility in particle size measurement. Equipped with high-sensitivity detectors, it delivers precise and reliable data. The analyzers come with integrated advanced software, for data collection and analysis processes. Complies with industry standards, ensuring quality and reliability in performance. Additionally, its automated functions simplify operation making particle analysis more efficient.
Laser Particle Size Analyzer LSA-39LS is equipped with a photoelectric detector with a measurement range of 0.1 to 300 µm for analyzing particles in liquid suspensions. It is designed for high-sensitivity analysis and equipped with 39 channels with a volume of 350 ml. Our analyzer provides automated features with one key switch operation such as optical alignment, water supply, drainage, and ultrasonic dispersion. It offers < 2 minutes of test time and provides data results in different formats.
Channel Number | Measurement Range | Test Speed | Price | Quantity | Add Cart | Get Quote |
39 | 0.1 to 300 µm | <2 min/time | N/A | N/A | N/A |
Laser Particle Size Analyzer LSA-100LS is incorporated with a highly sensitive ring photoelectric detector with a measuring range from 0.1 to 2000 µm. It is employed with dry-turbulence dispersion mode and consists of 100 channels for analyzing dry powder samples. Our analyzer with test speed of <1 minute and generates results for particle distribution, cumulative value curve, and typical particle sizes.
Channel Number | Measurement Range | Accuracy Error | Price | Quantity | Add Cart | Get Quote |
100 | 0.1 to 2000 µm | <1% (National Standard Sample D50) | N/A | N/A | N/A |
Laser Particle Size Analyzer LSA-90LS is incorporated with a multi-element silicon photodiode detector with a measuring range of 0.01 to 1000 μm. It features 90 channels with a capacity of 350 ml facilitating precise particle size distribution analysis. Our analyzer offers automated operations such as optical alignment, water supply, drainage, bubble removal, and ultrasonic dispersion through a one-key switch. It provides a test time of less than 2 min and supports results in various formats.
Channel Number | Measurement Range | Test Speed | Price | Quantity | Add Cart | Get Quote |
90 | 0.1 to 1000 µm | <2 min/time | N/A | N/A | N/A |
Laser Particle Size Analyzer LSA-87LS is equipped with a multi-element silicon photo-diode detector and offers a measuring range of 0.01 to 2000 µm. It accommodates 87 channels with a capacity of 350 ml sample. Our analyzer offers rapid test analysis within < 2 seconds and provides results in various formats. It is enhanced with various automated features such as optical alignment, water supply, drainage, bubble removal, and ultrasonic dispersion through one-key operation.
Channel Number | Measurement Range | Test Speed | Price | Quantity | Add Cart | Get Quote |
87 | 0.1 to 2000 µm | <2 min/time | N/A | N/A | N/A |
Laser Particle Size Analyzer LSA-40LS is equipped with a high-sensitive ring photoelectric detector and offers a measuring range from 0.1μm to 300 μm. It is designed with a dry-turbulence dispersion mode that analyzes the dry powder materials within < 1 minute. Our analyzer accommodates 40 detector channels for efficient characterization. It features an automatic optical path calibration system that enhances the accuracy and reliability of measurements.
Channel Number | Measurement Range | Accuracy Error | Price | Quantity | Add Cart | Get Quote |
40 | 0.1 to 300 µm | <1% (National Standard Sample D50) | N/A | N/A | N/A |
Laser Particle Size Analyzer LSA-127LS offers a combination of dual beam and multiple spectral detection mechanisms with a measuring range of 0.01 to 2000 μm. Our analyzer can accommodate 127 channels with a capacity of 350 ml. It provides a test period of < 2 minutes to analyze rapidly particle sizes within liquid samples. It features one key switch automated operation including optical alignment, water supply, drainage, bubble removal and ultrasonic dispersion.
Channel Number | Measurement Range | Test Speed | Price | Quantity | Add Cart | Get Quote |
127 | 0.1 to 2000 µm | <2 min/time | N/A | N/A | N/A |
Laser Particle Size Analyzer LSA-227LS
Laser Particle Size Analyzer LSA-227LS offers measuring ranges of 0.01 to 2000 µm and 0.1 to 2000 µm for dry and wet samples respectively. It accommodates 127 wet channels and has rapid analysis within < 2 minutes. For analyzing dry samples, it consists of 100 channels and a has test period time of less than 1 minute. Our analyzer supports automatic optical path alignment that ensures operational efficiency and performance.
Channel Number | Measurement Range | Accuracy Error | Price | Quantity | Add Cart | Get Quote |
Wet: 127 Dry: 100 |
Wet: 0.01 to 2000 µm Dry: 0.1 to 2000 µm |
Wet and Dry: <1% (National Standard Sample D50) | N/A | N/A | N/A |
Submit your inquiry.
our experts will promptly respond to you.